STERILISATION
Main purposes :
To disinfect contaminated materials : sterilise the dental equipments
minimise the risk of transmission of micro-organisms
promote safe work environments
STERILISATION EQUIPMENT
MAIN
AUTOCLAVE
HOT AIR STERILISER
CHEMICAL AUTOCLAVES
OTHERS
HOT WATER STERILISER
GLASS BEAD STERILISER
CHEMICAL SYSTEM
UV
AUTOCLAVE
Temperature – the correct temperature must be maintained for the specified time
Cleanliness – the equipment must be clean to enable sterilisation
Circulation – the chamber must be designed to allow circulation around the equipment
Moisture – steam must be used in the sterilisation process.
AUTOCLAVE
best method for dental equipment
effective in killing bacteria and virus
safe for practicer
for all purpose (dental equipment)
simple --- safe time
high electricity voltage
relatively expensive
Temp : 121oC, 15 mnt or 134oC, 4 mnt
Jacket autoclave & non jacket autoclave
Components of the autoclave :
Boiler
Basket
Basket support
Drainage tap
Lid
Lid Clamps
Air Outlet valve
Safety valve
Temperature or pressure gauge
HOT AIR STERILISER
simple electric oven
alternative to autoclave
metals and glass instruments
instruments --- not corrode
take longer time
temp. 106oC (320o F), 2 hours
CHEMICAL AUTOCLAVES
formaldehid-alcohol vapor pressure
relatively fast
temp. 132oC (0.15-0.3 mpascal) for 20 mnt
dry method
not corrode or damage instuments
safety --- questionable
this methods are not in wide use
HOT WATER STERILISATION
the last choice
inefficient
cross contamination of instruments
soak the instuments in hot water
temp. 100oC, 20 mnt
corrode or damage the instruments
GLASS BEAD STERILISER
disinfecting endodontic instruments during use
glass bead put into ceramic pot and heated electrically
endodontic instrument inserted
not totally sterile --- handle (shank)
glass bead can be stuck to instrument surface --- transferred to root canal
replaced with salt
CHEMICAL SYSTEM
cold chemical sterilising
activated glutaradehid
the instruments soaked in a bath of solution for 8 hours
air trap in part of inst --- not sterile
Instrument must be clean
anti-corrosion buffering agent --- prevent the corrosion
ULTRAVIOLET LIGHTING
sterilisation for large space
can be installed in dental chairs
activated at night
UV radiation
good for instrument (cabinet etc) are illuminated directly
Specific sterilisation problem
Elevator
Hand istruments
Forceps and orthodontic pliers
Handpieces
Space disinfection